Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Clin Chem Lab Med ; 59(11): 1878-1884, 2021 10 26.
Article in English | MEDLINE | ID: covidwho-1341521

ABSTRACT

OBJECTIVES: Numerous analytical systems, rapidly made available on the market throughout the SARS-CoV-2 pandemic, aim to detect COVID-19, and to continuously update and improve the same systems. Medical laboratory professionals have also developed in-house analytical procedures in order to satisfy the enormous volume of requests for tests. These developments have highlighted the need control the analytical procedures used in order to guarantee patient safety. The External Quality Assessment (EQA) Scheme, an important quality assurance tool, aims to guarantee high standard performance for laboratory and analytical procedures. The aim of the present study was to report on the results collected in an experimental EQA scheme for the serological diagnosis of SARS-CoV-2. METHODS: All qualitative results collected in the different EQA surveys were summarized in order to identify the percentage of laboratory results in relation to typology of antibodies, results and samples. RESULTS: A total of 4,867 data sets were collected. The analysis of EQA data made, demonstrates a better agreement among laboratories results for total Ig than single immunoglobulins (IgG, IgM, IgA) in the case samples positive for SARS-CoV-2, and a wide divergence between IgM results for positive samples (only 34.9% were correct). Results for negative controls and specificity controls demonstrated a better overall agreement than results for positive samples. CONCLUSIONS: Working in collaboration with the IVD manufacturers, laboratory professionals must strive to achieve harmonization of results, and to develop well-defined protocols complying with the ISO 15189 requirements.


Subject(s)
Antibodies, Viral/immunology , COVID-19/diagnosis , SARS-CoV-2/immunology , Serologic Tests/methods , Antibodies, Viral/blood , COVID-19/immunology , Humans , Immunoglobulin A/blood , Immunoglobulin A/metabolism , Immunoglobulin G/blood , Immunoglobulin G/metabolism , Immunoglobulin M/blood , Immunoglobulin M/metabolism , Pilot Projects , Quality Assurance, Health Care , Retrospective Studies , Sensitivity and Specificity , Severity of Illness Index
2.
Clin Chem Lab Med ; 59(8): 1444-1452, 2021 07 27.
Article in English | MEDLINE | ID: covidwho-1186618

ABSTRACT

OBJECTIVES: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT50) Ab titers. METHODS: A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. RESULTS: Assay imprecision ranged from 3.98 to 12.18% being satisfactory at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0 and 92.5%, respectively. A total of 281 leftover samples results of the PRNT50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT50 titer at univariate (ρ=0.689) and multivariate (ρ=0.712) analyses. CONCLUSIONS: SARS-CoV-2 S-RBD IgG assay shows satisfactory analytical and clinical performances, and a strong correlation with sera neutralizing activity.


Subject(s)
Antibodies, Neutralizing/immunology , Immunoglobulin G/immunology , Neutralization Tests/methods , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/immunology , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19/pathology , COVID-19/virology , Child , Female , Humans , Immunoassay/methods , Immunoglobulin G/blood , Male , Middle Aged , Protein Subunits/immunology , SARS-CoV-2/isolation & purification , Severity of Illness Index , Young Adult
4.
EBioMedicine ; 62: 103101, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-1023542

ABSTRACT

BACKGROUND: Reliable high-throughput serological assays for SARS-CoV-2 antibodies are urgently needed for the effective containment of the COVID-19 pandemic, as it is of crucial importance to understand the strength and duration of immunity after infection, and to make informed decisions concerning the activation or discontinuation of physical distancing restrictions. METHODS: In 184 serum samples from 130 COVID-19 patients and 54 SARS-CoV-2 negative subjects, the analytical and clinical performances of four commercially available chemiluminescent assays (Abbott SARS-Cov-2 IgG, Roche Elecsys anti-SARS-CoV-2, Ortho SARS-CoV-2 total and IgG) and one enzyme-linked immunosorbent assay (Diesse ENZY-WELL SARS-CoV-2 IgG) were evaluated and compared with the neutralization activity achieved using the plaque reduction neutralization test (PRNT). FINDINGS: Precision results ranged from 0.9% to 11.8% for all assays. Elecsys anti-SARS-CoV-2 demonstrated linearity of results at concentrations within the cut-off value. Overall, sensitivity ranged from 78.5 to 87.7%, and specificity, from 97.6 to 100%. On limiting the analysis to samples collected 12 days after onset of symptoms, the sensitivity of all assays increased, the highest value (95.2%) being obtained with VITRO Anti-SARS-CoV-2 Total and Architect SARS-CoV-2 IgG. The strongest PRNT50 correlation with antibody levels was obtained with ENZY-Well SARS-CoV-2 IgG (R2adj = 0.569). INTERPRETATION: The results confirmed that all immunoassays had an excellent specificity, whereas sensitivity varied across immunoassays, depending strongly on the time interval between symptoms onset and sample collection. Further studies should be conducted to achieve a stronger correlation between antibody measurement and PRNT50 in order to obtain useful information for providing a better management of COVID-19 patients, effective passive antibody therapy, and developing a vaccine against the SARS-CoV-2 virus. FUNDING: None.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Serological Testing , COVID-19 , SARS-CoV-2 , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/immunology , Female , Humans , Male , Middle Aged , SARS-CoV-2/immunology , SARS-CoV-2/metabolism
5.
Clin Chem Lab Med ; 58(7): 1081-1088, 2020 06 25.
Article in English | MEDLINE | ID: covidwho-937249

ABSTRACT

Background Coronavirus disease 2019, abbreviated to COVID-19, represents an emerging health threat worldwide as, after initial reports in China, it has continued to spread rapidly. The clinical spectrum of the disease varies from mild to severe acute respiratory distress syndrome (ARDS). Moreover, many patients can be asymptomatic, thus increasing the uncertainty of the diagnostic work-up. Laboratory tests play a pivotal role in the diagnosis and management of COVID-19, the current gold standard being real-time reverse transcription polymerase chain reaction (rRT-PCR) on respiratory tract specimens. However, the diagnostic accuracy of rRT-PCR depends on many pre-analytical and analytical variables. The measurement of specific COVID-19 antibodies (both IgG and IgM) should serve as an additional, non-invasive tool for disease detection and management. Methods The imprecision of the MAGLUMI™ 2000 Plus 2019-nCov IgM and IgG assays (Snibe, Shenzhen, China) was assessed by adopting the Clinical and Laboratory Standards Institute (CLSI) EP15-A3 protocol. Linearity of dilution and recovery was evaluated by means of mixes of high-level pools and low-level pools of serum samples. Immunoglobulin time kinetics were evaluated using a series of serum samples, repeatedly collected from COVID-19-positive patients at different times, from <5 days up to 26-30 days. Results Findings at the analytical validation of the assay carried out according to the CLSI EP15-A3 guideline demonstrated that imprecision and repeatability were acceptable (repeatability was <4% and <6% for IgM and IgG, respectively, whilst intermediate imprecision was <6%). In addition, results of dilution and recovery studies were satisfactory. The kinetics of COVID-19 antibodies confirmed previously reported findings, showing a rapid increase of both IgM and IgG after 6-7 days from the symptom onset. IgG had 100% sensitivity on day 12, whilst 88% was the higher positive rate achieved for IgM after the same time interval. Conclusions The findings of this study demonstrate the validity of the MAGLUMI 2000 Plus CLIA assay for the measurement of specific IgM and IgG in sera of COVID-19 patients, and for obtaining valuable data on the kinetics of both (IgM and IgG) COVID-19 antibodies. These data represent a pre-requisite for the appropriate utilization of specific antibodies for the diagnosis and management of COVID-19 patients.


Subject(s)
Betacoronavirus/immunology , Coronavirus Infections/immunology , Immunoenzyme Techniques/methods , Pneumonia, Viral/immunology , Antibodies, Viral/blood , COVID-19 , China , Clinical Laboratory Techniques/methods , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Kinetics , Luminescent Measurements/methods , Pandemics , Real-Time Polymerase Chain Reaction , SARS-CoV-2
8.
Clin Chim Acta ; 509: 1-7, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-436406

ABSTRACT

BACKGROUND: The evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibody (Ab) assay performances is of the utmost importance in establishing and monitoring virus spread in the community. In this study focusing on IgG antibodies, we compare reliability of three chemiluminescent (CLIA) and two enzyme linked immunosorbent (ELISA) assays. METHODS: Sera from a total of 271 subjects, including 64 reverse transcription-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 patients were tested for specific Ab using Maglumi (Snibe), Liaison (Diasorin), iFlash (Yhlo), Euroimmun (Medizinische Labordiagnostika AG) and Wantai (Wantai Biological Pharmacy) assays. Diagnostic sensitivity and specificity, positive and negative likelihood ratios were evaluated using manufacturers' and optimized thresholds. RESULTS: Optimized thresholds (Maglumi 2 kAU/L, Liaison 6.2 kAU/L and iFlash 15.0 kAU/L) allowed us to achieve a negative likelihood ratio and an accuracy of: 0.06 and 93.5% for Maglumi; 0.03 and 93.1% for Liaison; 0.03 and 91% for iFlash. Diagnostic sensitivities and specificities were above 93.8% and 85.9%, respectively for all CLIA assays. Overall agreement was 90.3% (Cohen's kappa = 0.805 and SE = 0.041) for CLIA, and 98.4% (Cohen's kappa = 0.962 and SE = 0.126) for ELISA. CONCLUSIONS: The results obtained indicate that, for CLIA assays, it might be possible to define thresholds that improve the negative likelihood ratio. Thus, a negative test result enables the identification of subjects at risk of being infected, who should then be closely monitored over time with a view to preventing further viral spread. Redefined thresholds, in addition, improved the overall inter-assay agreement, paving the way to a better harmonization of serologic tests.


Subject(s)
Betacoronavirus , Coronavirus Infections/blood , Coronavirus Infections/diagnosis , Pneumonia, Viral/blood , Pneumonia, Viral/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/standards , Serologic Tests/standards , Adolescent , Adult , Aged , Aged, 80 and over , Betacoronavirus/isolation & purification , COVID-19 , Child , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Female , Humans , Male , Middle Aged , Pandemics , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2 , Serologic Tests/methods , Young Adult
9.
Clin Chim Acta ; 507: 164-166, 2020 Aug.
Article in English | MEDLINE | ID: covidwho-125378

ABSTRACT

Validation studies of serological antibody tests must be properly designed for clinical, epidemiological and Public Health objectives such as confirmation of suspected COVID-19 cases, certification of seroconversion after infection, and epidemiological surveillance. We evaluated the kinetics of IgM, IgA and IgG SARS-CoV-2 antibodies in COVID-19 patients with confirmed (rRT-PCR) infection. We found that the IgA response appears and grows early, peaks at week 3, and it is stronger and more persistent than the IgM response. Further longitudinal investigations of virus-specific antibodies functions and of their protective efficacy over time are needed.


Subject(s)
Antibodies, Viral/blood , Betacoronavirus/isolation & purification , Coronavirus Infections/blood , Coronavirus Infections/diagnosis , Glycoproteins/blood , Immunoglobulin A/blood , Pneumonia, Viral/blood , Pneumonia, Viral/diagnosis , Adult , Aged , Aged, 80 and over , COVID-19 , Female , Humans , Longitudinal Studies , Luminescent Measurements/methods , Male , Middle Aged , Pandemics , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2 , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL